Moxy Hotel

Birmingham

About this project.

Critical mechanical smoke ventilation products, ensuring a hotel’s safety and compliance with fire regulations.
Project Name
Moxy Hotel
Location
Birmingham
Sector
Commercial
Client
Vastint UK BV
"Sertus’ ability to adapt and meet our tight deadlines was impressive. Their products and service exceeded our expectations, ensuring a smooth and successful project."
Andrew Cobden, Managing Director
About this case study:
1
Challenge

During the latter stages of the Moxy Hotel project, an unexpected challenge arose when a significant redesign of the building’s layout required a last-minute adjustment to the smoke ventilation system. The redesign involved multiple high-rise floors and complex internal structures, which complicated the integration of smoke control systems. Sertus was tasked with rapidly adapting the mechanical smoke ventilation solution to meet the revised layout while ensuring compliance with stringent fire safety regulations.

2
Solution

To address this challenge, Sertus delivered a flexible and comprehensive mechanical smoke ventilation system. The system’s design allowed for seamless integration with the revised building layout. When activated by a fire alarm, the system initiates by opening the head of the stair vent and the shaft dampers on the affected floor, while keeping other dampers closed to contain smoke. The Roof Mechanical Pod then kicks in, efficiently extracting smoke from the critical areas and drawing in fresh air through the stair core to facilitate safe evacuation. This adaptive approach ensured the system remained effective despite the redesign challenges. 

3
Project Results & Key Benefits
  • Timely Adaptation: Successfully adapted to last-minute design changes, delivering the products on schedule. 
  • Enhanced Safety: Provided robust smoke control, improving safety for all hotel occupants. 
  • Efficient Operation: Ensured effective smoke extraction and fresh air supply, maintaining clear evacuation routes. 
  • High-Quality Products: Utilised Roof Mechanical Pod, Shaft Louvre Dampers, and Roof Single Leaf vents that met rigorous standards. 
  • Regulatory Compliance: All products adhered to the necessary fire safety regulations and standards.
The products we used:
Roof Single Leaf - Residential (RSL-R)
View
Shaft Louvre Damper - Residential (SLD-R)
View
Sertus Pod Original
View
Next Case Study

Fulneck Place

Mechanical smoke ventilation solution to combat severe heat build-up and enhance safety in a high-efficiency residential building.
Next Case Study
Get in touch.
Want to learn more about our products? 😊